FLTR Turbine Flowmeter

CeYeKo Stainless Steel Turbine Flowmeters

CeYeKo FLTR series turbine flow meters have the features: high accuracy, good repeatability, convenient installation / maintenance, simple structure etc. Liquid flows through the turbine housing causing an internal rotor to spin. 

Properties

As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment.

Technical Specifications

Applications

FLTR series liquid turbine flowmeter is a kind of speed instrument, which has the advantages of high accuracy, good repeatability, simple structure, small pressure loss and convenient maintenance. It is used to measure the volume flow of low viscosity liquid in closed pipe. In the petroleum, chemical, metallurgy, water supply, paper and other industries with a wide range of applications.

Wetted Components

  • Housing: Standard – 304 Stainless Steel (Optional – 316 Stainless Steel)
  • Bearings and Shaft: Tungsten Carbide
  • Rotor: Standard – 2Cr13 Stainless Steel (Optional – Alloy CD4Mcu)
  • Retaining Rings: 316 Stainless Steel

Protection Level:

IP65

Performance

  • Repeatability: ±0.2%
  • Accuracy: Standard: ±1% of reading
  • Optional: ±0.5% of reading

Output Signal: (Where applicable)

  • Sensor: Pulse signal (Low Level: ≤0.8V; High Level: ≥8V)
  • Transmitter: 4 to 20 mA DC current signal
  • Signal Transmission Distance: ≤1,000 m

Electrical Connections:

  • Basic Type: Hausman Connector or three-core cable: ISO M20×1.5 Female

Flange Connections:

  • For standard product, the flange follows GB/T 9119-2000 (ISO 7005-1) RF (Raised Face)

Operation Conditions

Ambient:

  • Temperature: -10°C to +55°C
  • Pressure: 86 to 106 KPa
  • Relative Humidity: 5% to 90%

Fluid Temperature and Pressure:

  • Temperature: -20°C to +110°C
  • Pressure: Fluid pressure should be limited according to rating.

Power Supply:

  • Sensor: +12V DC (Optional: +24V DC)
  • Transmitter: +24V DC
  • Field Display Type B: Integral 3.2V Lithium Battery (Others available on request)
  • Field Display Type C: +24V DC

Flow Range Table

Nominal Diameter

Standard Flow

Range

Extended Flow

Range

Standard Pressure

Custimized Pressure Rating

(mm)

( inch )

(m³/h)

(m³/h)

PN

(Bar) – Flange Fitting

4⅛”0,04 … 0,250,04 … 0,4Thread: PN63120, 160, 250
6¼”0,1 … 0,60,06 … 0,6Thread: PN63120, 160, 250
10⅜”0,2 … 1,20,15 … 1,5Thread: PN63120, 160, 250
15½”0,6 … 60,4 … 8Thread: PN63; Flange: PN2540, 63, 120, 160, 250
20¾”0,8 … 80,45 … 9Thread: PN63; Flange: PN2540, 63, 120, 160, 250
251″1 … 100,5 … 10Thread: PN63; Flange: PN2540, 63, 120, 160, 250
321 ¼”1.5 … 150,8 … 15Thread: PN63; Flange: PN2540, 63, 120, 160, 250
401 ½”2 … 201 … 30Thread: PN63; Flange: PN2540, 63, 120, 160, 250
502″4 … 402 … 40Flange: PN2540, 63, 120, 160, 250
652 ½”7 … 704 … 70Flange: PN2540, 63, 120, 160, 250
803″10 … 1005 … 100Flange: PN2540, 63, 120, 160, 250
1004″20 … 20010 … 200Flange: PN1640, 63, 120, 160, 250
1255″25 … 25013 … 250Flange: PN1625, 40, 63, 120, 160
1506″30 … 30015 … 300Flange: PN1625, 40, 63, 120, 160
2008″80 … 80040 … 800Flange: PN1625, 40, 63, 120, 160

Cautions For Installation

Mounting Positions:

  • Turbine flow meters should be installed at the place in compliance with the requirements below:
    • Easy maintenance
    • No electromagnetic interface
    • No vibration
    • Away from heat source

Mounting Orientation:

  • All turbine flow meters are designed to measure flow in only one direction. The direction is indicated by the arrow on the body.

Required Lengths of Straight Runs

  • Flow altering device such as elbows, valves and reducers can affect accuracy.

See Diagram 1 for typical flow meter system installation.

Diagram 1. Typical Flow Meter System Installation

Diemensions

Standard Thread connection is used according to different flow models.

Dimensions of Thread Connection Flowmeter

Nominal Diameters

L

Thread Connections

( mm )

( inch )

( mm )

4

⅛”279

G ½”

6

¼”270G ½”

10

⅜”390

G ½”

15

½”75

G 1″

20

¾”80

G 1″

25

1″100

G 1 ¼”

32

1 ¼”140

G 2″

401 ½”140

G 2″

50

2″

150

G 2 ½”

Standard DIN Flange connection is used according to different flow models.

DIN FLANGE FLOWMETER DIMENSIONS

Nominal Diameter

L

D

K

Bolt Hole Dia d

No of Bolt Hole n

( mm )

( inch )

( mm )

( mm )

( mm )

( mm )

( Pcs )

15

½”75

95

65144

20

¾”80

105

75144

25

1″100

115

85144

32

1 ¼”140140100144

40

1 ½”140150110184

50

2″

150165125184
65

2 ½”

170

185145184
803″

200

200160188
1004″

220

220

180188
1255″250

250

210188
1506″300

285

240228
2008″360

340

295

22

12

FLTR Turbine Flowmeter Installation Guide